700kw AC Generator Load Banks for Australia Helps to Prevent Glazing with generator Tester

Model: KPLB-700
Testing capacity: 0 – 700 kw
Type of load:Resistive, PF = 1.0
Duty: Continuous
Cooling system: Industrial grade axial fan
Phase: Available at both single and three phase
Rated testing voltage: 110-480 VAC
Rated Frequency: 50/60 Hz
Dimensions (LWH)(mm): 1900*1600*1900
Weight: 1400 Kg(500kw)

Keep your generator fleet operating efficiently.

resistive load 700kW
inductor
800kW Load Bank
Resistive-loadbank-1500-2000kw-5
resistive load 700kW
inductor
2018 800kW Load Bank yellow-3
Resistive-loadbank-1500-2000kw-5
previous arrowprevious arrow
next arrownext arrow
Load Bank Description
  1. Resistive type of load, PF = 1.0. Stainless steel sheathed elements manufactured from high grade magnesium oxide.
  2. Rated testing voltage: AC 3P4W, 110-480V 50/60 Hz.
  3. Cooling mode: Forced air-cooled, fans mounted on the side of the load bank blow horizontally. Testing power or external utility power supply for fans.
  4. Working mode: Load step control
    Total testing capacity ranges from 0kw to the max consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the max, any load combination is achievable. Load step resolution is 10kw.
  5. Load bank features world-famous components to ensure reliable performance and longer service life including:
    SCHNEIDER contactors.
    Siemens switches, knobs and indicators.
    ABB Circuit breakers.
    OMRON intermediate relays.
    PHOENIX terminal blocks.
  6. Parameter measuring accuracy grade: 0.3
  7. Load control accuracy: ± 5%.
  8. Load bank protections: Over heating protection, cooling fans failure protection and over load protection with alarm.
  9. Control mode: Two control modes available:
    A)Local manual control;
    B)Optional: Manual control via a remote control panel (max control distance is 30m).
  10. Parameter display and measurement:
    Control panel contains a LOVATO Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc.
    (Optional: A professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing). “
  11. Operating environment:
    Altitude: ≤ 3000m above sea level. Ambient temp: -10~+50 ℃
    Relative humidity: ≤ 80% ventilated environment without explosive or corrosive dust. Not allowed to use in rainy outdoor environment.