300kw Stainless Steel Heater Generator Test Load Bank with CE

300kw load bank for generator testing
300kw load bank with tester
500, 600, 700 kW Resistive Load Banks
LOAD BANK KPLB-300 01
LOAD BANK KPLB-300 02
LOAD BANK KPLB-300 03
LOAD BANK KPLB-300 07
LOAD BANK KPLB-300 09
previous arrowprevious arrow
next arrownext arrow

Type of load: Resistive, PF = 0.8-1.0
Duty: Continuous
Cooling system: Industrial grade axial fan
Phase: Available at both single and three phase
Rated testing voltage: 110-480 VAC
Rated Frequency: 50/60 Hz

Load bank is a simulating load test equipment used for generators, UPS, battery banks etc power systems load test.

Product Details >>

KEYPOWER GENERATOR TESTER SPECIFICATIONS
Measurement Range Accuracy Resolution Overload
Voltage (V) 10.0~500.0V ± (0.4% reading+0.1%range) 0.1V 600V
Current (A) 0.030~5.000A ± (0.4% reading+0.1%range) 0.001A 6A
Power According to volt range
&  current range
Power factor =1.0 <200W 0.1W
± (0.4% reading+0.1% range) ≥200W 1W
Power factor =0.5 ≥2kW 10W
± (0.8% reading+0.2% range)
Power Factor 0.20~1.00 ±0.02 0.001
Frequency 45~65Hz ±0.2Hz 0.01Hz
Running 45~65Hz ±0.2Hz 0.01Hz
Energy
(kWh)
99999kWh  Power factor= 1.0 0.001kwh
± (0.4% reading+0.1% range)
Power factor=0.5
± (0.8% reading+0.2% range)
Harmonic Analysis
(%)
2-50 times
and total harmonic
Models You Can Choose
Model Testing 
capacity
Type 
of
 load
Duty Cooling 
system
Phase Rated 
Testing 
Voltage
Rated
 Frequency
Dimensions   
   (L*W*H)
 (mm)
Weight
 (kg)
KPLB-125 0 – 100 kw Resistive
or
Reactive,
PF =
1.0 or 0.8
Continuous Industrial
grade
axial fan
Available
at both
single
and
three
phase
110-480
VAC
50/60 Hz 960*960*1400 770
KPLB-250 0 – 200 kw 1300*1200*1570 1100
KPLB-375 0 – 300 kw 1600*1200*1700 1700
KPLB-500 0 – 400 kw 1600*1400*1700 2060
KPLB-625 0 – 500 kw 2100*1560*1700 3200
KPLB-750 0 – 600 kw 2100*1560*1700 3600
KPLB-875 0 – 700 kw 2100*1560*1800 4000
KPLB-1000 0 – 800 kw 2100*1660*1900 4730
KPLB-1250 0 – 1000 kw 2200*1900*2150 5000
KPLB-2500 0 – 2000 kw 20 ft container 13200

Specifications
100-2000KW Load Bank for Generator Load Test:
1.Premium components
2.Durable and reliable
3.Easy to transport

1. Resistive type of load, PF = 1.0. Stainless steel sheathed elements manufactured from high grade magnesium oxide.
2. Rated testing voltage: AC 3P4W, 110-480V 50/60 Hz.
3. Cooling mode: Forced air-cooled, fans mounted on the side of the load bank blow horizontally. Testing power or external utility power supply for fans.
4. Working mode: Load step control
Total testing capacity ranges from 0kw to the max consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the max, any load combination is achievable. Load step resolution is 10kw.
5. Load bank features world-famous components to ensure reliable performance and longer service life including:
     SCHNEIDER contactors.
     Siemens switches, knobs and indicators.
     ABB Circuit breakers.
     OMRON intermediate relays.
     PHOENIX terminal blocks.
6.  Parameter measuring accuracy grade: 0.3
7. Load control accuracy: &plusmn; 5%.
8. Load bank protections: Over heating protection, cooling fans failure protection and over load protection with alarm.
9. Control mode: Two control modes available:
A)Local manual control;
B)Optional: Manual control via a remote control panel (max control distance is 30m).
10. Parameter display and measurement:
Control panel contains a LOVATO Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc.
(Optional: A professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing). ”
11. Operating environment:
Altitude: &le; 2500m above sea level. Ambient temp: -15~+55 ℃
Relative humidity: 95% ventilated environment without explosive or corrosive dust. Not allowed to use in rainy outdoor environment.